Overtone Lab

How do you read an SPL meter, from A-weighting to Leq and L90?

Short answerdB SPL is sound pressure relative to 20 µPa. A-weighting discounts low frequencies the way the ear does at moderate levels, C-weighting barely does, Z is flat. Leq is the energy average over a period, so 10 minutes at 70 dB and 10 at 80 dB give 77.4 dB, not 75. L90 is the level exceeded 90% of the time, the usual measure of background noise.

A sound level meter reports one number, but that number depends on three settings: the frequency weighting, the time weighting and the statistic. Two meters showing different readings in the same room are often both right, set differently.

What does dB SPL mean?

Sound pressure level is Lp = 20 × log₁₀(p ÷ p₀), with p the RMS sound pressure and p₀ = 20 µPa, roughly the threshold of hearing at 1 kHz. Some anchors:

Pressure Level
20 µPa 0 dB SPL
1 Pa 94 dB SPL, the usual calibrator level
10 Pa 114 dB SPL
20 Pa 120 dB SPL

Doubling the pressure adds 6 dB. Doubling the power, for example two equal uncorrelated sources instead of one, adds 3 dB.

What do A, C and Z weighting do?

The ear is less sensitive to low and very high frequencies, and the shortfall depends on level. IEC 61672-1 defines filters that a meter applies before it computes the level:

Frequency A C Z
31.5 Hz −39.4 dB −3.0 dB 0
63 Hz −26.2 dB −0.8 dB 0
125 Hz −16.1 dB −0.2 dB 0
250 Hz −8.6 dB 0.0 dB 0
500 Hz −3.2 dB 0.0 dB 0
1 kHz 0.0 dB 0.0 dB 0
2 kHz +1.2 dB −0.2 dB 0
4 kHz +1.0 dB −0.8 dB 0
8 kHz −1.1 dB −3.0 dB 0

A-weighting (dBA) is the standard for noise exposure and environmental noise. It discounts bass heavily, so a room with a strong 50 Hz hum can read quietly in dBA. C-weighting (dBC) is nearly flat and is used for peak levels and for loud music, where low frequencies carry much of the energy. Z-weighting is no weighting at all within the meter's range.

A large gap between dBC and dBA readings of the same sound means it has a lot of low-frequency energy. That is a quick way to tell whether a noise problem needs bass treatment.

What are Fast and Slow?

Time weighting sets how quickly the reading follows the sound. Fast uses a 125 ms time constant and follows speech and music. Slow uses 1 s and steadies a fluctuating reading so it can be read by eye. Neither is an average over the whole measurement; for that you need Leq.

What is Leq, and why isn't it the arithmetic mean?

Leq, the equivalent continuous level, is the steady level that would carry the same sound energy over the period. Because decibels are logarithmic, the levels are converted to energy, averaged, and converted back:

Leq = 10 × log₁₀( (1 ÷ T) × Σ tᵢ × 10^(Lᵢ ÷ 10) )

Worked example: 10 minutes at 70 dBA and 10 minutes at 80 dBA.

  • Energies: 10^7.0 = 10,000,000 and 10^8.0 = 100,000,000.
  • Average: (10,000,000 + 100,000,000) ÷ 2 = 55,000,000.
  • Leq = 10 × log₁₀(55,000,000) = 77.4 dBA.

The loud half dominates. The arithmetic mean, 75 dBA, understates the exposure. That is why occupational limits are written as Leq over a working day, and why a short loud event raises an Leq so much.

What do L10, L50 and L90 mean?

Statistical levels describe how often a level is exceeded during the measurement:

  • L10 is exceeded 10% of the time. It tracks intermittent loud events such as passing traffic.
  • L50 is the median level.
  • L90 is exceeded 90% of the time. It is the usual measure of background noise: the floor the sound sits on when the events stop.

The gap between L10 and L90 shows how much a noise varies. A steady fan has L10 close to L90; a street has them far apart.

Overtone Lab's SPL Meter on iPhone: 69.0 dBA Fast, with a level-over-time trace and its Leq, L10, L50 and L90 markers
The SPL Meter: A-weighted level, Fast, with Leq and the L-statistics on the trace

How do you calibrate a phone microphone?

A phone measures in dB relative to digital full scale (dBFS), not in dB SPL. The step between the two is a fixed offset for a given microphone and input path, and calibration finds it:

  1. Put a known level at the microphone: an acoustic calibrator (94 dB at 1 kHz is common), or a steady sound measured by a reference meter held beside the phone.
  2. Read the phone's level in dBFS and enter the reference level.
  3. The difference is the offset, stored for that input. Every later reading on that input is shifted by it.

Calibrate each input separately: the built-in microphone, a headset and a USB measurement microphone each need their own offset. Phone microphones also limit what calibration can fix. Their frequency response is shaped for speech, they may roll off below 100 Hz, and they overload at high levels. A phone is not a Class 1 or Class 2 meter under IEC 61672, which specifies tolerances across frequency, level and temperature that phones are not tested against.

Where does Overtone Lab fit?

Overtone Lab's SPL Meter measures A, C or Z weighted level, Fast or Slow, with Leq and L10 / L50 / L90 from a 0.1 dB histogram. Calibration is stored per input and shared with the Spectrum Analyzer. Until an input is calibrated the meter labels its level Uncalibrated, because it is still relative to full scale. When a reading cannot be trusted, for example while the input is clipping, it shows no number rather than a wrong one.

The app also has an SPL calculator for the inverse-square law and for summing sources. It runs offline on iPhone, iPad and Mac.

Frequently asked questions

Why does my phone read differently from a dedicated meter?

Usually a different weighting or time constant, an uncalibrated input, or the microphone's frequency response. Match the settings, calibrate against the meter, and compare a steady sound rather than a fluctuating one.

Is dBA or dBC right for measuring a concert?

Both are used. Noise-exposure limits are written in dBA (Leq); venue and event limits often add a dBC limit as well, to control bass.

How much does distance change the level?

From a small source in open space, each doubling of distance lowers the level by about 6 dB. Indoors, the level stops falling once the reverberant field dominates.

Sources

  • IEC 61672-1:2013, Electroacoustics: Sound level meters, Part 1: Specifications: frequency weightings A, C and Z, time weightings F and S, performance classes.
  • ISO 1996-1:2016, Acoustics: Description, measurement and assessment of environmental noise, Part 1: equivalent continuous level and percentile levels.
  • Leo L. Beranek and Tim Mellow, Acoustics: Sound Fields, Transducers and Vibration, 2nd edition (Academic Press, 2019).